You send 12 months of interval data and a BAS trend export. We return a ranked, priced, defensible list of what your building is wasting. Already a customer? Sign in.
Guided demo
Try it on a campus.
Nine buildings in Tampa, two years of 15-minute meter data, BAS trends on the science building, bills and a capital plan. Walk the six stops or ask the building a question.
Pelorus EngineeringBuildingsNew analysisDocsdemo · Bay Palms University
Start where leadership starts: which buildings, how much, and how sure are we. Point at the natatorium — worst decile against its peers — and at Hillsborough Administration, the top-quartile control with almost nothing to find.
Bay Palms University is a synthetic demonstration campus — not a customer result.
Example
What a finding actually looks like.
AHU-X05 · Chiller-1
Equipment running outside its occupancy schedule
185 hours of operation outside the occupied window, across 69 separate events — 185 h × 64 kW ≈ 11,840 kWh.
$4,252/yr
Estimated savings
physical
Pricing method — stated, not hidden
medium
Confidence — with the reason given
Medium, and it says why: 122 days of data, but the chiller capacity is still a type default — confirm it and this becomes high.
Illustrative, from a synthetic demonstration building — not a customer result.
The difference
Why the numbers hold up.
Anything can put a dashboard on your data. The question your CFO will ask is where a number came from — so every one of ours answers it.
Three pricing methods, always stated: physics-based, capacity-based, or measured directly from the meter — shown on the face of every finding.
16 of the 96 rules are diagnostic and claim no dollars at all, by design. Comfort and sensor problems are still surfaced and ranked — just never inflated into savings.
Explicit confidence on every estimate, driven by data length and whether equipment capacities were confirmed — not a vague score.
Cascading faults are suppressed, so one root cause is not counted five times.
Verification follows IPMVP Option A, B or C, reporting the ASHRAE Guideline 14 fitness metrics (CV(RMSE), NMBE) — so a savings claim can stand up to a utility incentive review.
An assumptions register listing every judgement the analysis made.
Deliverables
What lands on your desk.
A prioritised list of faults — each with dollars per year, effort, and payback.
A work list your team can act on: assign an owner, set a due date, mark it fixed.
An interactive report, and a board-ready deck, carrying your own branding.
Calculation packages (Excel) behind every number, for the engineer who asks.
Ongoing monitoring once a building is set up — a weekly in-app digest of what is new, what persists, and what your team has cleared.
Fault library
Explore the rules
Every one of the 96 fault-detection rules has a public page explaining what the fault means, why it matters and what to do about it. Detector thresholds stay inside the product.
Twelve months of interval electricity data at 15-minute or hourly resolution (your utility provides it, often as Green Button), a BAS or BMS trend export if you have one, and a recent utility bill so savings are priced at your real tariff. Nothing is installed in the building.
How are savings priced?
Three methods, always stated on the finding: physics-based (a rule-specific model of the wasted energy), capacity-based (equipment capacity, duty and fault hours) or measured directly from the meter. Every number is priced at your actual tariff, including demand charges, with the assumptions listed.
What is a diagnostic rule?
A rule that surfaces a comfort, reliability or data-quality problem but claims no dollar savings, by design. Sixteen of the 96 rules are diagnostic; a biased sensor or an under-ventilated classroom is still ranked, just never inflated into savings.
How long does an analysis take?
Typically a few days from receiving the data. Once a building is set up, monitoring runs on its own and a weekly digest reports what is new, what persists and what your team cleared.
What do we receive?
A prioritised fault list with dollars per year, effort and payback; a work list with owners and due dates; an interactive report and a board-ready deck carrying your branding; and the calculation packages behind every number.
Which faults does it detect?
96 rules across whole-building meters, air handlers (including ASHRAE Guideline 36 fault conditions FC01–FC16), VAV boxes, zones and indoor air quality, central plant, packaged rooftop units, heat pumps and VRF, and dedicated outdoor-air and exhaust systems. Every rule is explained in the public fault library.
Screens
The product, screen by screen.
Captured from the product on the same synthetic campus the demo above uses.
Portfolio: the whole campus, rankedBay Palms University is a synthetic demonstration campus — not a customer result.Building overview: Ybor Athletics & NatatoriumBay Palms University is a synthetic demonstration campus — not a customer result.Fault work listBay Palms University is a synthetic demonstration campus — not a customer result.Report: a finding with its calculation openBay Palms University is a synthetic demonstration campus — not a customer result.Weekly monitoring digestBay Palms University is a synthetic demonstration campus — not a customer result.Operations: today's prioritiesBay Palms University is a synthetic demonstration campus — not a customer result.Ask the buildingBay Palms University is a synthetic demonstration campus — not a customer result.
Start here
Send us 12 months of data.
We will analyse it and come back with what your building is wasting and what it is worth. No commitment to go further.
Interval electricity data — 12 months, 15-minute or hourly. Your utility provides this (often called Green Button), or we can request it with your authorisation.
A BAS/BMS trend export, if you have one — Niagara, Metasys, Tracer, Desigo, EcoStruxure and similar all export CSV.
A recent utility bill, so savings are priced at your real tariff.
That is everything. Nothing to install, nothing to buy.
Contact
Request a demo
Tell us which building bothers you most and what data you have. A Pelorus engineer replies within one business day.