Learn

Interactive tools for understanding how buildings and their HVAC systems really behave. Built for engineers, operators and students. Free to use.

Free

CBECS Explorer

Enter one building, or paste a whole portfolio, and see how its energy use intensity ranks against a weighted peer group drawn from the 6,436 buildings in the EIA 2018 Commercial Buildings Energy Consumption Survey. Weighted percentile, peer distribution, and the savings envelope to the median and top quartile. Nothing is uploaded until you ask us to follow up.

Don’t have a year of kWh or an EUI to hand? Send us the bills instead. Utility Bill Analyzer works out annual use, cost and EUI from them, and the first building is free. Start from the bills

Free

A day in the life of a campus energy plant

An interactive 3D central plant serving nine college buildings: three chillers staging with the load, cooling towers, pumps around a decoupler, and steam boilers through a summer peak and a January morning. Lift the roof, open the live one-line schematic, then switch on twelve plant faults, from low chilled-water ΔT to setpoints that never reset, each simulated for a full year.

Free

A day in the life of an air handler

An interactive 3D office floor with its air handler as a glass box: economizer dampers, coils and fan, a duct main and ten VAV boxes through a July afternoon, a January morning and a mild day of free cooling. Open the live air-side schematic, then switch on thirteen air-side faults, from a locked-out economizer to an air handler scheduled around the clock, each simulated for a full year.

Free

A day in the life of a hotel’s energy

An interactive 3D 120-room hotel: every guest room on its own heat pump with one outdoor unit per floor, an outdoor-air unit with a recovery wheel that never stops, and the lobby, fitness room and laundry around it, through a hot Tuesday, a cold Wednesday, a spring swing and a half-sold Sunday night. Watch the rooms sell, fill and empty, open the live one-line schematic, then switch on fourteen heat-pump, outdoor-air and exhaust faults, from empty rooms conditioned all night to a reversing valve stuck in cooling, each simulated for a full year.

Free

Fly over a year of energy

A year of a building’s electric meter as a 3D landscape you fly over: each day a ridge, each hour a step, the height the power being drawn. The demo school’s six findings stand on it with what each costs, and the land sinks when they are fixed. Then your own interval file, read in your browser and never uploaded, with your night floor as the water level and your peaks as pins.

New: play the models. Rogue Shift: keep a plant healthy for a year in 90 seconds · Fault Detective: name the fault from its trends · Lights Out: close up the school

Screening-level results for learning; confirm with engineering calculations before design. More tools are listed at learn.pelorusengineering.com.

Invite-only products

These run on your data and need an account. Ask for access and a Pelorus engineer will set you up.

Your first building is free.

Pick the one that bothers you most and send what you have: twelve months of interval data, a BAS trend export, or just the bills. You get a screening-level report of what is happening inside it and what it is worth. One building per organisation, no commitment to go further.